  • Understanding the 75°C vs 90°C column in Ampacity Table. . .
    The columns indicate how much amperage is required to raise the temperature of that size conductor to that column's temperature under standardized conditions So a 2 0 XHHW will reach 75°C at 135A and 90°C at 150A The wire insulation is good for 90°C, so for sizing the wire, we can use the
  • Table 300. 5 interpretation - Electrician Talk
    For a given column of Table 300 5 ("minimum cover requirements") there is a potential overlap of the various rows The one that concerns me at present is Column 2 (IMC and RMC conduit) If it's buried in a trench below 2" of concrete or equivalent, but also goes under a parking area in a
  • NEC Article about mixed voltages in conduit - Electrician Talk
    NEC Article about mixed voltages in conduit Jump to Latest 26K views 11 replies 8 participants last post by wildleg Jul 9, 2017 G
  • Equipment room receptacle. - Electrician Talk
    NEC 2020, 210 63 (B) now requires a receptacle outlet in electrical rooms containing panelboards, switchboards, or switchgear The intent is to ensure there’s a convenience outlet for servicing the electrical equipment (like plugging in test equipment, task lighting, or even a laptop)
  • Required Clearance - Electrician Talk
    Good Morning Everyone, I Recently obtained a lead on a service upgrade My question to the community pertains to working clearance of other utilities I could not find any references in the 2020 NEC regarding clearances to gas lines I'm aware of certain electrical equipment being readily
  • Gas station wiring requirements - Electrician Talk
    NEC 2017 514 8 Underground Wiring ENHANCED CONTENT Fuel spilled in the vicinity of gasoline dispensers seeps into the ground and could migrate into underground electrical conduits Therefore, all conduits installed below the hazardous locations of a motor fuel dispensing facility are required to be sealed within 10 feet of the point of emergence from below grade This boundary seal minimizes
  • NEC and running multiple 3 Phase feeders in single conduit
    Does NEC allow running multiple 480V 3 Phase Power load conductors in a single conduit instead of running each 3 phase loads conductors in separate conduits?
  • Difference between NEC and CEC - Electrician Talk
    The main difference between the CEC and the NEC is that the CEC uses the Canadian Wire Gauge, and the NEC uses the American Wire Gauge :whistling2: A bit too provocative for the average person
  • Receptacle above drop ceiling? - Electrician Talk
    Is there anything in the NEC prevenenting a receptacle from being installed above a drop ceiling? Either in a plenum or non-plenum ceiling? Can't seem to find an article I know Cords or SO cords cannot be ran in a drop ceiling
  • 80% rule? - Electrician Talk
    80% rule applies to continious loads such as motors, lighting or any load expected to be on 3 hours or more A breaker is rated for 100% of the noncontinious load which may include outlets or other small appliances There are fully rated breakers panels that are rated for continious use And will be listed for this application It is a good practice to load branch circuits to a fraction of